Payne Multipoise Furnace, 80% AFUE, 80,000 BTU, Ultra-Low NOx (SCAQMD/SJVAPCD/BAAQMD Compliant), Single Stage, 18 Speed ECM, 115/1

Item
PG80MSUA60080C
  • California Prop 65
80 ULTRA LOW NOx GAS FURNACE
The PG80MSUA 4-way Multipoise Gas Furnaces offer features not found in other single-stage 80% gas furnaces. Improved serviceability with the 3 digit status display and NFC enabled board allowing setup via the service tech app. These models meet the nitrogen oxides (NOx) emission limit of 14 nanograms/joule for the South Coast Air Quality Management District, San Joaquin Valley Air Pollution Control District in California, and Bay Area Air Quality Management District.

EFFICIENCY
• 80% AFUE
• 40K, 60K, 80K, 100K BTUh
• Ultra-low NOx emissions - meets the nitrogen oxides (NOx) emission limit of 14 nanograms/joule for the South Coast Air Quality Management District, San Joaquin Valley Air Pollution Control District in California, and Bay Area Air Quality Management District.

TECHNOLOGY
• Single-stage gas valve
• Two-stage cooling capability
• Multi 18-Speed, Constant Torque (MCT) ECM blower motor
• Pre-mix burner
• SiN Igniter for physical and electrical robustness and durability
• Variable speed inducer motor
• Stainless steel, tubular heat exchanger 

PERFORMANCE
• Pre-mix burner with variable speed inducer
• Insulated blower compartment for quiet operation, and inner door for tighter sealing
• Draft safeguard switch designed to ensure proper furnace venting
• Dual Fuel compatible

DESIGN AND INSTALLATION
• Approved for installations up to 5,400 feet
• Versatile venting for tight-fit applications
• On-board NFC antenna makes setup a tap away when using the service technician app
• Factory shipped for natural gas, not convertible to propane
• Four-position furnace: Upflow, Horizontal Right, Horizontal Left, Downflow (with 6 different vent options)
• Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193

 

Specification
Fuel Type Natural Gas Only
Stages Single Stage
Ignition Type Silicon Nitride Hot Surface
Gas Connection Size 1/2 - NPT
AFUE 80
Blower Speeds Multi-Speed ECM
Electrical
Hertz 60
MCA 14.2
MOCP 20
Phase 1
Voltage 115
Safety Standards
California Prop 65 Yes
Weights and Dimensions
Operating Weight (lbs) 149
Exterior Dimensions (D) (inches) 29.000000
Exterior Dimensions (W) (inches) 21.000000
Exterior Dimensions (H) (inches) 33.250000
Shipping Weight (lbs) 149.000000
General
Tier Payne